Industrial Drive Repair and Replacement
3079–3084 of 3094
-
GE
GE 6KGP43040X9XBXA1 Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- 6KGP43040X9XBXA1
- Part #:
- 6KGP43040X9XBXA1
-
FUJI ELECTRIC
FUJI ELECTRIC FRN250G1S-4U Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- FRN250G1S-4U
- Part #:
- FRN250G1S-4U
-
FUJI ELECTRIC
FUJI ELECTRIC FRN600G1S-4U Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- FRN600G1S-4U
- Part #:
- FRN600G1S-4U
-
FUJI
FUJI FRN010F1S-2DY Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- FRN010F1S-2DY
- Part #:
- FRN010F1S-2DY
-
FUJI
FUJI FRN060G1S-2U Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- FRN060G1S-2U
- Part #:
- FRN060G1S-2U
-
FANUC
FANUC A06B-6121-H030#H550 Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- A06B-6121-H030#H550
- Part #:
- A06B-6121-H030#H550
AC/DC Drive Repair Process:
To begin the repair on an AC/DC drive a visual inspection is performed.
- Next meters and signature analysis devices are used to component test.
- Common failure parts such as capacitors, drive and output transistors, power supplies, SCR’s, and firing circuits are checked first.
- Common failure parts are tested and replaced as necessary
- Drive is then powered up
- While powered up the power supplies are checked as are the outputs for proper wave form
- A dummy load is applied to the drive and the output waveform is checked with an oscilloscope
- If proper output is seen the dummy load is removed and the drive is fully load tested with the proper motor and with a dynamometer
- It is scoped again for proper wave form
- Entire unit is cleaned and retested