How Aeration Differs From Cavitation in Hydraulic Systems

Aeration and cavitation both put bubbles in hydraulic oil, both make a pump noisy, and both shorten its life, which is why they get mistaken for each other. The difference is where the bubbles come from. 

Aeration is outside air getting into the suction side of the pump. Cavitation happens when the pump tries to draw more oil than its inlet can supply, so pressure at the inlet drops until cavities form in the oil, then collapse once they reach higher pressure. The term sometimes also covers air already dissolved in the oil coming out of solution, but either way, cavitation bubbles start inside the system. One is a leak. The other is a pump going hungry.

Where the bubbles come from

Aeration starts wherever air can get into the suction side:

  • A loose fitting or cracked hose on the suction line
  • A worn shaft seal on a fixed-displacement pump
  • A reservoir level low enough for a vortex to form over the suction line
  • A pump turning in the wrong direction

Cavitation starts wherever the pump can’t get enough oil:

  • A plugged suction strainer, filter, or reservoir breather
  • Cold oil too thick to flow into the inlet quickly
  • Drive speed higher than the pump can feed
  • Too much lift between the reservoir and the pump inlet

Cold starts are a common case. A pump that screams for the first several minutes on a cold morning and quiets as the oil warms is usually cavitating on thick oil.

How to tell them apart

The quickest checks take nothing more than eyes, ears, and a few simple supplies:

  • Cavitation produces a steady, high-pitched whine, while aeration sounds more erratic.
  • Foam in the reservoir points to aeration, since outside air is what whips the oil into froth.
  • Oil brushed around the suction fittings that briefly quiets the pump means air is getting in at a fitting.
  • Shaving cream spread over the shaft seal that develops holes indicates the seal is drawing air.

A vacuum gauge at the pump inlet settles what the senses can’t. A starving pump pulls a deep vacuum at the inlet. An aerating pump usually reads closer to normal, because the air leaking in relieves the vacuum.

Why the damage differs

Cavitation does its damage with force. Each collapsing cavity strikes nearby metal. Over time, those impacts erode the inside of the pump. Aeration does its damage through the fluid. Air carried through the system makes actuators spongy and erratic, speeds up fluid degradation, and generates heat as bubbles compress under pressure, in some cases enough to scorch seals and leave carbon deposits. The damage from the two is roughly equal, and either one ends in pump failure if it runs long enough.

Find the source first

The bubbles look alike, but the fixes point in opposite directions. Tightening suction fittings won’t feed a pump that’s starving behind a clogged strainer, and cleaning the strainer won’t stop a shaft seal from drawing air. Listening to the pump, looking at the reservoir, and putting a gauge on the inlet will sort out which problem is running before any parts get changed.

A noisy pump is already taking damage, whether the bubbles came from outside the system or inside it. Global Electronic Services repairs gear, vane, and piston pumps and looks for the cause behind the wear before the pump goes back in service. Contact us for Repair, Sales & Service of Industrial Electronics, Servo Motors, AC & DC Motors, Hydraulics & Pneumatics — don’t forget to like and follow us on Facebook, LinkedIn, YouTube, and X!

Speak to a Repair Expert