Easergy P5M30 48-250V 3CT 1CSH 4VT 16DI-12DO

Schneider Electric REL50411 Easergy P5M30 48-250V 3CT 1CSH 4VT 16DI-12DO

Product information
Key Features
- range of product Easergy P5
- product or component type Protection relay
- relay application Motor
- product reference P5M30-BACB-HAAAA-AAAA
- mounting case size 30TE
Schneider Electric
- Model #:
- REL50411
- Part #:
- REL50411
REL50411 Schneider Electric | BUY OR REPAIR
Overview
Medium Voltage Distribution and Grid Automation > Protection Relays by Range > Easergy Protection > Easergy P5 Protection Relays > REL50411
Features
- range of product Easergy P5
- product or component type Protection relay
- relay application Motor
- product reference P5M30-BACB-HAAAA-AAAA
- mounting case size 30TE
- device mounting Flush
- mounting mode Withdrawable
- power supply 48...250 V DC 100...230 V AC
- measuring inputs : 1/5 A CT phase current 3 : CSH residual current 1 : VT voltage 4
- number of sensors 0 temperature sensor(s) 0 arc sensor(s)
- number of Digital Inputs (DI) 16
- number of Digital Outputs (DO) 11 DO 1 watchdog
- number of analogue inputs
- number of analogue outputs
- communication ports USB port 2 front
- communication protocols -
- cybersecurity Password protection Port hardening
- protection functions Phase overcurrent 50/51 Directional phase overcurrent 67 Earth fault overcurrent 50N/51N Directional earth fault 67N Transient earth fault 67NI Capacitor bank unbalance 2 Broken conductor 46 I2/I1 Cold load pick-up Switch ON to fault (SOTF) H2 detection H5 detection Breaker failure 50BF Directional active underpower 37P Fault locator 21FL Recloser 79 Negative sequence overcurrent 46 Overvoltage 59 Undervoltage 27 Earth fault overvoltage 59N Underfrequency 81/81N Rate of change of frequency 81R Synchro-check 25 Lockout relay 86 CT supervision VT supervision Programmable stages 99 Programmable curve
- measurement functions Current 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Phasor diagram of currents or voltages Current 2nd
- control functions 15th harmonics with THD Voltage 3-phase Voltage residual Voltage zero sequence Voltage positive sequence Voltage negative sequence Frequency
- controllable switchgear devices Switchgear control and monitoring Programmable switchgear interlocking Local/remote control
- number of setting groups 6 controlled + 2 monitored objects
- monitoring functions 4
- logs and records Trip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
- switchgear diagnosis type Event recording Disturbance recording Tripping context Relay maintenance
- connections - terminals CT/VT supervision ANSI code: 60 Trip circuit supervision ANSI code: 74
- software name Screw (digital input/output) Ring lugs (analog inputs and outputs)
- number of key ESetup Easergy Pro: virtual simulation test
- local signalling 7 customizable
- height LED 4 LED 10 tri-colour programmable
- width 176 mm
- 152 mm