circuit breaker Compact NSX160N, 50 kA at 415 VAC, Micrologic 5.2 A trip unit 160 A, 3 poles 3d

Schneider Electric LV430890 circuit breaker Compact NSX160N, 50 kA at 415 VAC, Micrologic 5.2 A trip unit 160 A, 3 poles 3d

Product information

Key Features
  • range Compact
  • product name Compact NSX
  • range of product NSX100...250
  • device short name Compact NSX160N
  • product or component type Circuit breaker
Schneider Electric
Model #:
LV430890
Part #:
LV430890
LV430890 Schneider Electric | BUY OR REPAIR

    Need a Quote Sent?

    Repair Price Guarantee: We’ll meet or beat any competitor’s repair price.

    We are committed to your privacy. Global Electronic Services uses the information you provide to contact you about our relevant content, products, and services. You may unsubscribe from these communications at any time. For more information, please review our Privacy Policy.

    Overview

    Low Voltage Products and Systems > Circuit Breakers and Switches > Molded Case Circuit Breakers – MCCBs > ComPact NSX > LV430890

    Features

    • range Compact
    • product name Compact NSX
    • range of product NSX100...250
    • device short name Compact NSX160N
    • product or component type Circuit breaker
    • device application Distribution
    • poles description 3P
    • protected poles description 3t
    • [In] rated current 160 A at 40 °C
    • [Ue] rated operational voltage 690 V AC 50/60 Hz
    • network type AC
    • network frequency 50/60 Hz
    • suitability for isolation Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2
    • utilisation category Category A
    • [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 480 V AC 50/60 Hz conforming to UL 508 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    • Performance level N 50 kA 415 V AC
    • trip unit name Micrologic 5.2 A
    • trip unit technology Electronic
    • trip unit protection functions LSI
    • control type Toggle
    • Circuit breaker mounting mode Fixed
    • [Ui] rated insulation voltage 800 V AC 50/60 Hz
    • [Uimp] rated impulse withstand voltage 8 kV
    • [Ics] rated service short-circuit breaking capacity 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    • mechanical durability 40000 cycles
    • mounting support Backplate
    Speak to a Repair Expert