circuit breaker Compact NSX100F, 36 kA at 415 VAC, TMD trip unit 40 A, 4 poles 4d

Schneider Electric LV429654 circuit breaker Compact NSX100F, 36 kA at 415 VAC, TMD trip unit 40 A, 4 poles 4d

Product information

Key Features
  • range Compact
  • product name Compact NSX
  • range of product NSX100...250
  • device short name Compact NSX100F
  • product or component type Circuit breaker
Schneider Electric
Model #:
LV429654
Part #:
LV429654
LV429654 Schneider Electric | BUY OR REPAIR

    Need a Quote Sent?

    Repair Price Guarantee: We’ll meet or beat any competitor’s repair price.

    We do not share personal information of our customers with anyone.

    Overview

    Low Voltage Products and Systems > Circuit Breakers and Switches > Molded Case Circuit Breakers – MCCBs > ComPact NSX > LV429654

    Features

    • range Compact
    • product name Compact NSX
    • range of product NSX100...250
    • device short name Compact NSX100F
    • product or component type Circuit breaker
    • device application Distribution
    • poles description 4P
    • protected poles description 4t
    • neutral position Left
    • [In] rated current 40 A at 40 °C
    • [Ue] rated operational voltage 690 V AC 50/60 Hz
    • network type AC
    • network frequency 50/60 Hz
    • suitability for isolation Yes conforming to EN 60947-2 Yes conforming to IEC 60947-2
    • utilisation category Category A
    • [Icu] rated ultimate short-circuit breaking capacity 10 kA at 600 V AC 50/60 Hz conforming to UL 508 25 kA at 480 V AC 50/60 Hz conforming to UL 508 85 kA at 240 V AC 50/60 Hz conforming to UL 508 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    • Performance level F 36 kA 415 V AC
    • trip unit name TM-D
    • trip unit technology Thermal-magnetic
    • trip unit protection functions LI
    • control type Toggle
    • Circuit breaker mounting mode Fixed
    • [Ui] rated insulation voltage 800 V AC 50/60 Hz
    • [Uimp] rated impulse withstand voltage 8 kV
    • [Ics] rated service short-circuit breaking capacity 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
    • mechanical durability 50000 cycles
    • mounting support Backplate
    Call for Help