Industrial Drive Repair and Replacement
7–12 of 3094
-
Part Number VHPSIC43188-1-R Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- VHPSIC43188-1-R
- Part #:
- VHPSIC43188-1-R
-
Part Number TVD6-200-10RS Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- TVD6-200-10RS
- Part #:
- TVD6-200-10RS
-
Part Number TYZ3-424-2284806 Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- TYZ3-424-2284806
- Part #:
- TYZ3-424-2284806
-
Part Number TLZ07BA Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- TLZ07BA
- Part #:
- TLZ07BA
-
Part Number Tpy3-415/480 -1200 I Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- Tpy3-415/480 -1200 I
- Part #:
- Tpy3-415/480 -1200 I
-
Part Number SLC-700-TWINPRO Drives Repair Maintenance and Troubleshooting Service — Replacement Parts Sales
- Model #:
- SLC-700-TWINPRO
- Part #:
- SLC-700-TWINPRO
AC/DC Drive Repair Process:
To begin the repair on an AC/DC drive a visual inspection is performed.
- Next meters and signature analysis devices are used to component test.
- Common failure parts such as capacitors, drive and output transistors, power supplies, SCR’s, and firing circuits are checked first.
- Common failure parts are tested and replaced as necessary
- Drive is then powered up
- While powered up the power supplies are checked as are the outputs for proper wave form
- A dummy load is applied to the drive and the output waveform is checked with an oscilloscope
- If proper output is seen the dummy load is removed and the drive is fully load tested with the proper motor and with a dynamometer
- It is scoped again for proper wave form
- Entire unit is cleaned and retested