Best Practices for Calibrating Your Manufacturing Sensors

Accurate sensor calibration is a critical aspect of modern manufacturing processes. In an industry where precision and reliability are paramount, sensors play a vital role in monitoring and controlling production parameters to ensure optimal performance and product quality. But sensors can drift over time, leading to inaccurate readings with repercussions on production efficiency and consistency. To mitigate these risks, it’s important to establish and follow best practices for sensor calibration.

Precalibration preparation

Before beginning the calibration process, conduct a benchmark test on the sensors to verify they need adjusting. If an adjustment is required, establish a calibration schedule so this essential equipment always operates at peak performance.

A controlled environment is often necessary for calibration. Variations in temperature or humidity can significantly influence results. For a smooth, accurate calibration process, your maintenance team must gather the appropriate equipment and tools, including a reference sensor, specialized software, and a calibration device. With proper precalibration preparation, you can eliminate the risks associated with incorrect measurement data.

Calibration procedures and best practices

Calibration procedures and best practices are essential to guarantee the accuracy, repeatability, and reliability of measurement systems and analytical instruments. Follow the steps below to perform sensor calibration the right way:

  1. Inspect and clean: Before starting the calibration process, inspect the device for signs of damage when the last calibration was conducted. Confirm the device is clean and fully functional.
  2. Establish calibration standards: Before making any adjustments, establish a reference or calibration standard linked to national or international standards and measurement systems. These are often available through the National Institute of Standards and Technology (NIST).
  3. Adjust sensor settings or trim values: Once you have identified the calibration standard, you can adjust the sensor’s output to match it. If the sensor has trim values, make the necessary adjustments to align the output with the standard.
  4. Perform a calibration test: With the sensor settings adjusted, it is time to perform a calibration test, ideally in a controlled environment. During the test, record the reading from the device and then compare it to the reference standard.
  5. Document the calibration results: Finally, document your calibration results in a certificate or report. Include details such as the date, reference standards used, deviation, and other helpful information.

Managing sensor deviations and out-of-tolerance situations

While the steps above may assist in ensuring accurate calibration results, deviations and out-of-tolerance sensors are always possible. The following tips can help you identify deviations and take the appropriate corrective actions:

  • Troubleshoot common calibration issues. Many calibration issues have easy solutions. Take time to follow a calibration schedule closely to prevent any complications with the potential to cause output deviation.
  • Implement corrective actions. When a calibration issue arises, address it immediately. Corrective measures may include calibration adjustment, repair, or preventive maintenance.
  • Document and report deviations. Any calibration deviations and corrective actions taken should be documented and reported. This can help improve future calibration processes and prevent similar out-of-tolerance issues.

Post-calibration verification and validation

Manufacturers should embrace continuous improvement in calibration management by taking proactive steps, such as:

  • Performing validation tests and evaluating the impact of calibration on process quality
  • Developing a system and regularly reviewing and updating calibration procedures
  • Incorporating calibration data into predictive maintenance programs
  • Training personnel on calibration best practices to maintain consistency

By following these steps to improve sensor post-calibration verification and validation, any manufacturer can achieve greater efficiency, accuracy, and quality in their calibration processes.

Are you having trouble with your sensors? You can always count on the professionals at Global Electronic Services. Contact us for all your industrial electronic, servo motor, AC and DC motor, hydraulic, and pneumatic needs — and don’t forget to like and follow us on Facebook!
Call for Help