Key Features
  • range TeSys
  • product name TeSys D
  • product or component type Contactor
  • device short name LC1D
  • contactor application Resistive load
Schneider Electric
Model #:
LC1D80004V7
Part #:
LC1D80004V7
LC1D80004V7 Schneider Electric | BUY OR REPAIR
Product Type *

We do not share personal information of our customers with anyone.

Overview

Low Voltage Products and Systems > Motor Starters and Protection Components > Contactors and Reversing Contactors > TeSys D > LC1D80004V7

Features

  • range TeSys
  • product name TeSys D
  • product or component type Contactor
  • device short name LC1D
  • contactor application Resistive load
  • utilisation category AC-1
  • poles description 4P
  • power pole contact composition 4 NO
  • [Ue] rated operational voltage Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC
  • [Ie] rated operational current 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • control circuit type AC at 50/60 Hz
  • [Uc] control circuit voltage 400 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
  • overvoltage category III
  • [Ith] conventional free air thermal current 125 A (at 60 °C) for power circuit
  • Irms rated making capacity 1100 A at 440 V for power circuit conforming to IEC 60947
  • rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit
  • associated fuse rating 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
  • average impedance 0.8 mOhm - Ith 125 A 50 Hz for power circuit
  • [Ui] rated insulation voltage Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1
  • electrical durability 0.8 Mcycles 125 A AC-1 at Ue <= 440 V
  • power dissipation per pole 12.5 W AC-1
  • Front cover Without
  • mounting support Rail Plate
  • standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • product certifications GL UL DNV CSA BV GOST RINA LROS (Lloyds register of shipping) CCC
  • connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end Power circuit: connector 1 cable(s) 4…50 mm²solid without cable end Power circuit: connector 2 cable(s) 4…25 mm²solid without cable end
  • tightening torque Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 9 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 9 N.m - on connector hexagonal screw head 4 mm
  • operating time 20...35 ms closing 6...20 ms opening
  • safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • mechanical durability 4 Mcycles
  • maximum operating rate 3600 cyc/h 60 °C
  • coil technology Without built-in suppressor module
  • inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 20 °C) 245 VA 50 Hz cos phi 0.75 (at 20 °C)
  • hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 20 °C) 26 VA 50 Hz cos phi 0.3 (at 20 °C)
  • heat dissipation 6…10 W at 50/60 Hz
  • contact compatibility M1