Power base, TeSys U, 3P, 32A/690V
Schneider Electric LUB32 Power base, TeSys U, 3P, 32A/690V
Product information
Key Features
- range TeSys
- product name TeSys U
- device short name LUB
- product or component type Non reversing power base
- device application Motor control Motor protection
Schneider Electric
- Model #:
- LUB32
- Part #:
- LUB32
LUB32 Schneider Electric | BUY OR REPAIR
Overview
Low Voltage Products and Systems > Motor Starters and Protection Components > Direct On Line Motor Starters > TeSys U > LUB32
Features
- range TeSys
- product name TeSys U
- device short name LUB
- product or component type Non reversing power base
- device application Motor control Motor protection
- poles description 3P
- suitability for isolation Yes
- [Ue] rated operational voltage 690 V AC for power circuit
- network frequency 40...60 Hz
- [Ith] conventional free air thermal current 32 A
- [Ie] rated operational current 32 A at <= 440 V 23 A at 500 V 21 A at 690 V
- utilisation category AC-44 AC-43 AC-41
- [Ics] rated service breaking capacity 50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
- auxiliary contact composition 1 NO + 1 NC
- auxiliary contacts type type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
- [Uc] control circuit voltage 24 V AC 50/60 Hz 24 V DC 48...72 V AC 50/60 Hz 48...72 V DC 110...240 V AC 50/60 Hz 110...220 V DC
- typical current consumption 200 mA at 24 V DC I maximum while closing with LUCM 220 mA at 24 V AC I maximum while closing with LUCA
- heat dissipation LUCB
- safety reliability level LUCC
- operating time LUCD 220 mA at 24 V DC I maximum while closing with LUCA
- mechanical durability LUCB
- LUCC
- LUCD 25 mA at 110...220 V DC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD 25 mA at 110...240 V AC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD 280 mA at 110...220 V DC I maximum while closing with LUCA
- LUCB
- LUCC
- LUCD 280 mA at 110...240 V AC I maximum while closing with LUCA
- LUCB
- LUCC
- LUCD 280 mA at 48...72 V AC I maximum while closing with LUCA
- LUCB
- LUCC
- LUCD 280 mA at 48...72 V DC I maximum while closing with LUCA
- LUCB
- LUCC
- LUCD 45 mA at 48...72 V AC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD 45 mA at 48...72 V DC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD 75 mA at 24 V DC I rms sealed with LUCM 80 mA at 24 V DC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD 90 mA at 24 V AC I rms sealed with LUCA
- LUCB
- LUCC
- LUCD
- 3 W for control circuit with LUCA
- LUCB
- LUCC
- LUCD 1.8 W for control circuit with LUCM
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- 35 ms opening with LUCA
- LUCB
- LUCC
- LUCD
- LUCM for control circuit 50 ms at >= 72 V closing with LUCA
- LUCB
- LUCC
- LUCD for control circuit 60 ms at 48 V closing with LUCA
- LUCB
- LUCC
- LUCD for control circuit 70 ms at 24 V closing with LUCA
- LUCB
- LUCC
- LUCD for control circuit 65 ms closing with LUCM for control circuit
- 15 Mcycles