Power base, TeSys U, 3P, 32A/690V

Schneider Electric LUB32 Power base, TeSys U, 3P, 32A/690V

Product information

Key Features
  • range TeSys
  • product name TeSys U
  • device short name LUB
  • product or component type Non reversing power base
  • device application Motor control Motor protection
Schneider Electric
Model #:
LUB32
Part #:
LUB32
LUB32 Schneider Electric | BUY OR REPAIR

    Need a Quote Sent?

    Price Guarantee: We’ll beat any competitor’s repair price by at least 10%.

    We do not share personal information of our customers with anyone.

    Overview

    Low Voltage Products and Systems > Motor Starters and Protection Components > Direct On Line Motor Starters > TeSys U > LUB32

    Features

    • range TeSys
    • product name TeSys U
    • device short name LUB
    • product or component type Non reversing power base
    • device application Motor control Motor protection
    • poles description 3P
    • suitability for isolation Yes
    • [Ue] rated operational voltage 690 V AC for power circuit
    • network frequency 40...60 Hz
    • [Ith] conventional free air thermal current 32 A
    • [Ie] rated operational current 32 A at <= 440 V 23 A at 500 V 21 A at 690 V
    • utilisation category AC-44 AC-43 AC-41
    • [Ics] rated service breaking capacity 50 kA at 230 V 50 kA at 440 V 10 kA at 500 V 4 kA at 690 V
    • auxiliary contact composition 1 NO + 1 NC
    • auxiliary contacts type type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
    • [Uc] control circuit voltage 24 V AC 50/60 Hz 24 V DC 48...72 V AC 50/60 Hz 48...72 V DC 110...240 V AC 50/60 Hz 110...220 V DC
    • typical current consumption 200 mA at 24 V DC I maximum while closing with LUCM 220 mA at 24 V AC I maximum while closing with LUCA
    • heat dissipation LUCB
    • safety reliability level LUCC
    • operating time LUCD 220 mA at 24 V DC I maximum while closing with LUCA
    • mechanical durability LUCB
    • LUCC
    • LUCD 25 mA at 110...220 V DC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD 25 mA at 110...240 V AC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD 280 mA at 110...220 V DC I maximum while closing with LUCA
    • LUCB
    • LUCC
    • LUCD 280 mA at 110...240 V AC I maximum while closing with LUCA
    • LUCB
    • LUCC
    • LUCD 280 mA at 48...72 V AC I maximum while closing with LUCA
    • LUCB
    • LUCC
    • LUCD 280 mA at 48...72 V DC I maximum while closing with LUCA
    • LUCB
    • LUCC
    • LUCD 45 mA at 48...72 V AC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD 45 mA at 48...72 V DC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD 75 mA at 24 V DC I rms sealed with LUCM 80 mA at 24 V DC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD 90 mA at 24 V AC I rms sealed with LUCA
    • LUCB
    • LUCC
    • LUCD
    • 3 W for control circuit with LUCA
    • LUCB
    • LUCC
    • LUCD 1.8 W for control circuit with LUCM
    • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    • 35 ms opening with LUCA
    • LUCB
    • LUCC
    • LUCD
    • LUCM for control circuit 50 ms at >= 72 V closing with LUCA
    • LUCB
    • LUCC
    • LUCD for control circuit 60 ms at 48 V closing with LUCA
    • LUCB
    • LUCC
    • LUCD for control circuit 70 ms at 24 V closing with LUCA
    • LUCB
    • LUCC
    • LUCD for control circuit 65 ms closing with LUCM for control circuit
    • 15 Mcycles