What Is Cogging in Servo Motors and Why Does It Happen?
Cogging is the torque variation felt as a permanent-magnet servo motor’s rotor turns. It is caused by the magnetic attraction between the rotor’s magnets and the stator’s iron teeth. It happens even with the motor unpowered, since the effect comes from the metal, not from current flowing through the windings.
Where cogging originates
Every time a rotor magnet lines up with a stator tooth, the magnetic circuit finds its path of least resistance, its lowest reluctance, and pulls the rotor toward that alignment. Between teeth, over a slot opening, reluctance is higher, and that pull drops off. As the rotor turns, it passes through that cycle of low and high reluctance over and over. The resulting pull-and-release is what gets felt as cogging.
Cogging is a narrower case of the broader torque ripple category. It exists purely from magnet-and-iron geometry, present with the motor unpowered. Other forms of torque ripple come from current commutation and only show up once the motor is running under power. The two get lumped together, but they originate from different physical mechanisms.

Why cogging shows up at low speeds
At running speed, inertia carries the rotor through each reluctance cycle smoothly enough that closed-loop control absorbs the variation before it shows up anywhere that’s noticeable. Slow the motor down, or stop it, and there’s nothing left to smooth it out.
That’s when cogging turns into jerky rotation, poor synchronism between the commanded and actual position, and a rotor that settles into one of a few preferred resting points once power cuts out rather than stopping where it was told to.
A pick-and-place head or an indexing table moving in small, precise steps spends most of its working life in that low-speed range, which is why cogging gets specified so carefully for those applications. Some engineers call this detent torque, since an unpowered rotor will click into one of those low-reluctance positions on its own.
What reduces cogging
Manufacturers design around cogging, rather than eliminate the underlying physics behind it, in a variety of ways:
- Skewing the stator slots or the magnets at a slight angle, so the reluctance transition happens gradually across the rotor’s length instead of all at once
- Using a non-linear ratio of poles to teeth, so the low- and high-reluctance points from different magnets don’t reinforce each other
- Widening the air gap between the magnet and tooth, which softens the attraction at the cost of some torque output
- Building the motor with an ironless or slotless winding, which removes the teeth and eliminates cogging by construction rather than reducing it
- Compensating electronically, since some servo drives run a calibration routine that maps the cogging pattern and cancels it out in the commanded torque

How much cogging is normal?
Cogging shows up on a spec sheet, not just in a failure report. Published figures for servo motor product lines typically run in the range of roughly 1.5% to 2% of the rated torque, presented as a normal design characteristic rather than a defect. A motor cogging within its published spec is behaving as designed.
What’s worth investigating is a change. A motor that used to run smoothly at low speed and now cogs noticeably more than it did indicates magnet or bearing damage rather than the inherent design trait every permanent-magnet motor has.
Cogging is a trait to manage, not a fault to chase
Every permanent-magnet servo motor cogs to some degree. That baseline is built into the design rather than a sign something’s wrong. The number that matters isn’t whether cogging exists but whether it’s still the same number it always was.