circuit breaker Compact NS1250H – Micrologic 2.0 A – 1250 A – 3 poles 3t

Schneider Electric 33258 circuit breaker Compact NS1250H – Micrologic 2.0 A – 1250 A – 3 poles 3t

Product information

Key Features
  • range Compact
  • product name Compact NS
  • range of product NS630b...1600
  • device short name Compact NS1250H
  • product or component type Circuit breaker
Schneider Electric
Model #:
33258
Part #:
33258
33258 Schneider Electric | BUY OR REPAIR

    Need a Quote Sent?

    Price Guarantee: We’ll beat any competitor’s repair price by at least 10%.

    We do not share personal information of our customers with anyone.

    Overview

    Low Voltage Products and Systems > Circuit Breakers and Switches > Molded Case Circuit Breakers – MCCBs > ComPact NS > 33258

    Features

    • range Compact
    • product name Compact NS
    • range of product NS630b...1600
    • device short name Compact NS1250H
    • product or component type Circuit breaker
    • device application Distribution
    • poles description 3P
    • protected poles description 3t
    • (In) rated current up to 65 °C 1250 A at 50 °C
    • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
    • network type AC
    • network frequency 50/60 Hz
    • suitability for isolation Yes conforming to IEC 60947-2
    • utilisation category Category B
    • [Icu] rated ultimate short-circuit breaking capacity 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2
    • trip unit name Micrologic 2.0 A
    • trip unit technology Electronic
    • trip unit protection functions LI
    • control type Rotary handle Toggle
    • Circuit breaker mounting mode Fixed
    • [Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
    • [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
    • [Ics] rated service short-circuit breaking capacity 52 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 31 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 37 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 48 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 52 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
    • mechanical durability 10000 cycles
    • power losses 44 W
    Call Now ButtonCall for Help